EAST EA900 1-3kVA UPS (1 kVA – 3 kVA)
- Technology
- Online (Double Conversion)
- Capacity
- 1–3 kVA
- Phase
- 1-phase in / 1-phase out
- High frequency on-line double conversion technology
- DSP control technology
- Active power factor correction (APFC), input power factor up to 0.99
- Output power factor 0.9/1.0
- Wide input voltage range (110 V ~ 300 Vac) and frequency range (40 ~ 70 Hz)
- Quick charging, 90% capacity restored in 3h (standard model)
- Advanced battery management (ABM) and cold start
- RS232 standard; USB / RS485 / SNMP / dry contacts optional
Notify me of a price drop
Your order text is prepared and copied — just send it.
Overview EAST EA900 1-3kVA UPS (1 kVA – 3 kVA)
The EAST EA900 G3 series is a high-frequency online double-conversion UPS rated from 1 to 3 kVA (models EA901, EA902 and EA903) with a 0.9/1.0 output power factor and zero transfer time. Efficiency reaches ≥92% in mains mode and ≥97% in ECO mode, and the LCD + LED display allows adjustment of the output voltage and battery parameters. The series is offered in two versions, standard (internal batteries) and long backup (external batteries), and is suitable for servers, network equipment, and sensitive medical and office equipment.
Key Features of the EA900 1-3kVA Series
- High-frequency online double-conversion technology
- DSP digital control
- Active power factor correction (APFC) with input power factor up to 0.99
- Output power factor 0.9/1.0
- Wide input voltage range (110 to 300 Vac) and 40 to 70 Hz frequency range
- Fast charging: 90% of battery capacity recovered in 3 hours (standard model)
- Advanced battery management (ABM) and cold start capability
- Standard RS232 communication; optional USB, RS485, SNMP and dry contact
Models in This Series
EA901, EA902, EA903
Technical specifications are based on the manufacturer's (EAST) official datasheet and may vary depending on product version and generation.
Purchase and Consultation
Ista Afagh Energy supplies this series together with capacity-selection consulting, battery sizing for the required backup time, installation and commissioning, and after-sales service. For current pricing and stock availability, add the product to your order basket or contact us.
Technical specifications
| Brand | EAST |
| Series | EA900 1-3kVA |
| Model | |
|---|---|
| Models | EA901, EA902, EA903 (standard S and long time H models) |
| Capacity | EA901: 1kVA / 1kW | EA902: 2kVA / 2kW | EA903: 3kVA / 3kW |
| Input | |
| Rated voltage | 208 / 220 / 230 / 240Vac |
| Input voltage range | 110 ~ 176Vac (linear derating between 50% and 100% load); 176 ~ 280Vac (no derating); 280 ~ 300Vac (derating 50%) |
| Frequency range | 40 ~ 70Hz (auto-sensing) |
| Power factor | ≥0.99 |
| Bypass voltage range | -25% ~ +15% (settable) |
| Input current THDi | ≤ 6% |
| Output | |
| Output voltage | 208 / 220 / 230 / 240Vac (settable via LCD) |
| Voltage regulation | ±1% |
| Output frequency | 45 ~ 55Hz or 55 ~ 65Hz (synchronized range); 50 / 60Hz ± 0.1Hz (battery mode) |
| Waveform | Sinusoidal |
| Output power factor | 0.9/1.0 |
| Output voltage THDv | ≤2% (linear load), ≤5% (non-linear load) |
| Crest factor | 3:1 |
| Overload | 105% ~ 125% for 1min, 125% ~ 150% for 30s, >150% for 300ms |
| Transfer time | Mains mode to battery mode: 0 ms; Inverter mode to bypass mode: 4 ms (typical) |
| Protections | Short-circuit, overload, overtemperature, battery discharge protection and fan testing protection |
| Battery | |
| Battery DC voltage | 24V / 36V / 48V / 72V / 96V (S and H versions depending on model) |
| Inbuilt battery (standard model) | 2×9Ah / 3×7Ah / 4×9Ah / 6×7Ah / 6×9Ah / 8×7Ah |
| Charging current | Standard model: 1A, long time model: 6A |
| Recharge time | Standard model: 90% capacity restored in 3 hours; Long time model: depend on the capacity of battery |
| Efficiency | |
| Efficiency (mains mode) | EA901: ≥90% | EA902: ≥91% | EA903: ≥92% |
| Efficiency (battery mode) | EA901: ≥85% | EA902: ≥86% | EA903: ≥87% |
| Efficiency (ECO mode) | EA901: ≥95% | EA902: ≥96% | EA903: ≥97% |
| Display & Communication | |
| Display | LCD + LED |
| Communications | RS232 (standard), USB / RS485 / dry contacts / SNMP (optional) |
| Model | |
| Standards | EN 62040-1, EN 62040-2, EN 61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2, IEC 62040-2, IEC 62040-1, IEC 62040-3 |
| Operating Environment | |
| Operating temperature | 0℃ ~ 40℃ |
| Storage temperature | -25°C ~ 55°C (without batteries) |
| Relative humidity | 0 ~ 95% (non-condensing) |
| Altitude | ≤ 1000m, derating 1% for each additional 100 m |
| IP rating | IP 20 |
| Noise level (at 1 m) | ≤ 50dB |
| Dimensions & Weight | |
| Dimensions (W×D×H) mm | EA901: 144×312×216 / 144×336×214 / 144×371×216 | EA902: 144×336×216 / 144×417×216 | EA903: 191×418×335 / 191×419×335 |
| Packaged dimensions (W×D×H) mm | EA901: 230×402×315 / 232×417×318 / 230×460×315 | EA902: 232×417×318 / 230×506×315 | EA903: 277×500×435 |
| Net weight (kg) | EA901: 11 / 6 / 12.8 / 6 / 16.4 / 10.5 | EA902: 23.1 / 10.5 / 24.3 / 11 | EA903: 29.4 / 11 |
| Gross weight (kg) | EA901: 11.3 / 6.9 / 14 / 7 / 17.8 / 11.6 | EA902: 24.7 / 12 / 25.9 / 12.5 | EA903: 31.1 / 12.5 |